Fronius Primo 8.2-1 WLAN/LAN/WEB Server inverter with simple standardized mounting system and maximum flexibility in system design.
The communicative inverter for the optimization of energy management
The Fronius Primo, in power categories between 3.0 and 8.2 kW, completes the SnapINverters range. This transformerless single phase inverter meets the needs of any home. Its innovative SuperFlex design offers maximum flexibility in system design and with the SnapINverter mounting system, installation and maintenance are easier than ever. It includes a communications package with WLAN connection, power management, numerous interfaces and much more, offering the user a comprehensive experience and complete information about their installation.
Technology
SNAP INVERTER TECHNOLOGY
The SnapINverter generation of inverters is characterized by its simple standardized mounting system. Installation and maintenance are easier than ever. One of the special characteristics in the design of the equipment is the separation between the connection area and the area of the power stages. Both zones are mounted separately. After mounting the lightweight wall bracket and the equipment cabling, the power stage is installed. The innovative housing opening concept makes assembly and service extremely easy. The inverter is hooked into the wall bracket to secure it afterwards. Therefore, in case of service it is not necessary to remove the entire inverter, but only the power stage. All wiring stays in place.
TECHNICAL DATA FRONIUS PRIMO
DATA IMPUT |
PRIMO 5.0-1 |
PRIMO6.0-1 |
PRIMO 8.2-1 |
Number of MPP followers |
2 |
Max input current (Idc max 1/ Idc max 2) |
12A/12A |
18A/18A |
Maximum short circuit current of MPP1/MPP2 (Isc pv) * |
24 A / 24 A |
36A/36A |
DC input voltage range (Udc min. - Udc max.) |
80 - 1000 V |
Commissioning voltage (start Udc) |
80 V |
MPP voltage range |
80 - 800 V |
Number of DC inputs |
2 + 2 |
Max PV generator output (Pdc max.) |
7,5 kWpico |
9,0 kWpico |
12,3 kWpico |
OUTPUT DATA |
PRIMO 3.0-1 |
PRIMO 3.5-1 |
PRIMO 3.6-1 |
Rated AC power (Pac,r) |
5.000 W |
6.000 W |
8.200 W |
maximum power output |
5.000 VA |
6.000 VA |
8.200 VA |
AC output current (Iac nom.) |
21,7 A |
26,1 A |
35,7 A |
Grid coupling (voltage range) |
1 ~ NPE 220 V / 230 V (180 V - 270 V) |
Frequency (frequency range) |
50 Hz / 60 Hz (45 - 65 Hz) |
Nonlinear distortion coefficient |
< 3 % |
Power factor (cos φac,r) |
0,85 - 1 ind. / cap |
GENERAL DATA |
PRIMO 3.0-1 |
PRIMO 3.5-1 |
PRIMO 3.6-1 |
Dimensions (height x width x depth) |
645 x 431 x 204 mm |
Weight |
21,5 kg |
protection type |
IP 65 |
protection class |
1 |
Overvoltage category (DC / AC) 1) |
2 / 3 |
nocturnal consumption |
< 1 W |
investor concept |
without transformer |
Refrigeration |
Regulated air cooling |
Facility |
Indoor and outdoor installation |
Ambient temperature range |
-40 - +55 °C |
Permissible air humidity |
0 - 100 % |
maximum altitude |
4.000 m |
DC connection technology |
4x X+ and 4 x DC screw terminals 2.5 - 16 mm² |
Main connection technology |
CONNECTION 3-pole AC screw terminals 2.5 - 16 mm² |
Certificates and compliance |
DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727,
AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 2)
|
Country of manufacture |
Austria |
PERFORMANCE |
PRIMO 5.0-1 |
PRIMO 6.0-1 |
PRIMO 8.2-1 |
Maximum performance |
98,1 % |
98,1 % |
98,1 % |
European Yield (ηEU) |
97,1 % |
97,3 % |
97,5 % |
MPP Fitting Performance |
> 99,9 % |
SAFETY EQUIPMENT |
PRIMO 5.0 |
PRIMO 3.5-1 |
PRIMO 3.6-1 |
DC insulation measurement |
Yes |
Overload behavior |
Duty point displacement, power limitation |
DC disconnector |
Yes |
Reverse polarity protection |
Yes |
INTERFACES |
PRIMO 5.0-1 |
PRIMO 6.0-1 |
PRIMO 8.2-1 |
WLAN / Ethernet LAN |
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
6 inputs and 4 digital inputs/outputs |
Wave Control Receiver Interface |
USB (Conector A) 2) |
Datalogging, inverter update via USB |
2 RJ 45 connectors (RS422) 2) |
Fronius Solar Net |
Warning output 2) |
Energy management (potential free relay output) |
Datalogger and web server |
Including |
External input 2) |
S0-Meter / Input interface for overvoltage protection |
RS485 |
Modbus RTU SunSpec or meter connection |
1) According to IEC 62109-1.
2) Also available in the light version.