Fronius Primo Gen24 3.0 Plus inverters allow you to produce energy in a flexible and profitable way.
Sustainable, reliable and future-proof: our Fronius GEN24 Plus hybrid inverter as the heart of a photovoltaic system enables flexible and cost-effective energy production and the connection of a storage battery in order to use self-generated solar energy for electric mobility and to generate electricity, heat or cold. Harness all the power of the sun for your private energy transition with Fronius GEN24 Plus.
Maximum flexibility: Fronius GEN24 Plus as the heart of your photovoltaic installation allows you not only to start your personal energy transition, but also to open the door to all the possibilities and advantages of solar energy.
Emergency power: For any situation Secure power supply: The Fronius GEN24 Plus allows you to choose between "PV Point" and "Full Backup", an emergency power supply for the whole house.
EASY INSTALLATION: Save time and money with fast and secure installation thanks to 180° quick-locking screws, quick-push connectors, and a well-designed wall-mounting system.
Support and tools Endless support: Efficient Fronius solutions for plant planning, assembly and monitoring are available free of charge. This increases customer satisfaction and minimizes the need for maintenance.
Data Sheet
PRIMO GEN24 PLUS |
Input Data |
Models |
3.0 |
3.6 |
4.0 |
Number of MPP followers |
|
2 |
DC input voltage range (Udc min - Udc max) |
V |
65-600 |
Rated input voltage (Udc,r) |
V |
400 |
Commissioning voltage (start Udc) |
V |
80 |
MPP voltage range |
V |
65 - 530 |
65 - 530 |
65 - 530 |
|
|
MPPT1 |
MPPT2 |
MPPT1 |
MPPT2 |
MPPT1 |
MPPT2 |
Max input current per MPPT (Idc max.) |
A |
22 |
12 |
22 |
12 |
22 |
12 |
Maximum input current per MPPT (Idc max) |
A |
36 |
19 |
36 |
19 |
36 |
19 |
Number of DC entries in the module field |
|
2 |
2 |
2 |
|
|
MPPT1 |
MPPT2 |
Total |
MPPT1 |
MPPT2 |
Total |
MPPT1 |
MPPT2 |
Total |
Max DC power |
W |
3110 |
3810 |
4140 |
Max PV generator output |
Wpico |
3750 |
3110 |
4500 |
4600 |
3810 |
5520 |
5000 |
4140 |
6000 |
Output Data |
Models |
3.0 |
3.6 |
4.0 |
Rated AC power (Pac,r) |
W |
3000 |
3680 |
4000 |
Apparent power |
VA |
3000 |
3680 |
4000 |
Max output power |
VA |
3000 |
3680 |
4000 |
|
|
220 VCA |
230 VCA |
220VCA |
230 VCA |
220VCA |
VCA |
AC output current nom. (@ 220 / 230V) |
A |
13,6 |
13 |
16,7 |
16 |
18,2 |
17,4 |
Grid coupling (Uac,r) |
V |
1~ NPE 220/230 (+20 %/-30 %) |
Frequency (frequency range fmin - fmax) |
Hz |
50/60 (45 - 65) |
Nonlinear distortion coefficient |
% |
< 2 |
Power factor (cos φac,r) |
|
0,8 - 1 ind. / cap |
Models |
3.0 |
3.6 |
4.0 |
PV Point Output Data |
Rated Output Power PV Point |
VA |
3000 |
3600 |
4000 |
Coupling to the PV Point network |
V |
1~ NPE 220/230 |
Transition time |
Seg. |
< 35 |
Models |
3.0 |
3.6 |
4.0 |
Output Data Full Backup2 |
rated output power "Full Backup" |
VA |
3000 |
3600 |
4000 |
Coupling to the grid "Full Backup |
V |
1~ NPE 220/230 |
Transition time |
Seg. |
< 35 |
Models |
3.0 |
3.6 |
4.0 |
Battery Connection |
Number of DC inputs |
|
1 |
Max input current (Idc max.) |
A |
22 |
DC input voltage range (Udc min - Udc max)3 |
V |
150-455 |
Battery DC connection technology |
|
Quick connectors by pressure of 2.5-10 mm² (1 unit BAT+ and 1 unit BAT-) |
Max DC input/output power 4 |
W |
3110 |
3810 |
4140 |
Max load power with AC4 coupling |
W |
3000 |
3680 |
4000 |
Compatible Batteries 5 |
|
BYD Battery-Box Premium HVS/HVM y LG RESU FLEX6 |
- Isc pv = Isc max. ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021
- The "Full Backup" option is available for Primo GEN24 from 3.0 to 6.0 Plus. For "Full Backup", additional external components are required for network switching. More detailed information can be found in the instruction manual.
- The inverter's AC derating occurs with a DC battery input voltage of 419.7V and higher.
- Depending on the connected battery.
- Depending on country-specific certification and availability 6 Except BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1 and LG RESU FLEX 17.2
Models |
3.0 |
3.6 |
4.0 |
General data |
Dimensions (height × width × depth) |
mm |
530 X 474 X165 |
Weight (inverter / with packaging) |
kg |
15,4/19 |
15,4/19 |
15,4/19 |
protection type |
|
IP66 |
protection class |
|
1 |
nocturnal consumption |
W |
< 10 |
Overvoltage category (DC/AC)7 |
|
2/3 |
investor concept |
|
without transformer |
refrigeration |
|
Active Ventilation Technology |
Facility |
|
Indoor and outdoor installation |
Ambient temperature range |
ºC |
-40a +60 |
Permissible air humidity |
% |
0-100 |
noise emission |
dB (A) |
<42 |
Max altitude |
M |
4000 |
DC PV connection technology |
|
Quick connectors by pressure of 2.5-10 mm² (4 units CC+ and 4 units CC-) |
AC connection technology |
|
3-pole AC push-in quick connector 2.5-10 mm² 3-pole push-in quick connector for emergency power 1.5-10 mm² PE screw terminals (2 pieces 2.5-16 mm² and 3 pieces 2.5-10mm²) |
Certificates and compliance 8 |
|
IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 y 16150, IEC 62116, IEC61727, G98/99 |
Emergency Power Features |
|
"PV Point" o "Full Backup" |
Country of manufacture |
|
Austria |
Life Cycle Analysis |
|
According to ÖNORM EN ISO 14040 and 14044 (verified by staff of the Fraunhofer IZM Institute) |
Models |
3.0 |
3.6 |
4.0 |
Performance |
Max performance |
% |
97,6 |
97,6 |
97,6 |
European performance (ηEU) |
% |
96,8 |
97,0 |
97,1 |
MPP Fitting Performance |
% |
>99,9 |
>99,9 |
>99,9 |
Models |
3.0 |
3.6 |
4.0 |
Safety equipment |
DC insulation measurement |
Integrated |
Overload behavior |
Travel to duty point, power limitation |
DC disconnector |
Integrated |
Reverse polarity protection |
Integrated |
Models |
3.0 |
3.6 |
4.0 |
interfaces |
WLAN/2 × Ethernet LAN |
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
6 digital inputs
6 digital inputs/outputs
|
Wave control receiver interface, power management |
Emergency stop (WSD) |
Integrated |
Datalogger and web server |
Integrated |
2 × RS485 |
Modbus RTU SunSpec (from another manufacturer) / Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot |