Fronius Symo Gen24 5.0 Plus inverter increases satisfaction and minimizes the need for maintenance.
Maximum flexibility Fronius GEN24 Plus .- As the heart of your photovoltaic installation, it allows you not only to start your personal energy transition, but also to open the door to all the possibilities and advantages of solar energy.
Easy installation Save time and money with fast and secure installation thanks to 180° quick-locking screws, quick snap connectors and a well-designed wall mounting system.
Support and tools Endless support: Efficient Fronius solutions for plant planning, assembly and monitoring are available free of charge. This increases customer satisfaction and minimizes the need for maintenance.
Emergency power for any situation Secure power supply: The Fronius GEN24 Plus allows you to choose between "PV Point" and "Full Backup", an emergency power supply for the whole house.
Characteristics of the FRONIUS Symo GEN24 5.0 Plus Hybrid Inverter
The FRONIUS Symo GEN24 5.0 Plus Hybrid Inverter is a grid connection inverter with 5kW output power, three-phase and without a transformer with a series of additional features compared to the normal Symo three-phase range. The generation of Fronius GEN24 Plus inverters stands out thanks to the different functions that it has integrated, such as energy management, WLAN connection, Ethernet connectivity and the easy integration of components from other manufacturers.
Among the most notable features are the following:
PV Point: It is an emergency power function built into the inverter itself. In the event of a power outage, the FRONIUS Symo GEN24 5.0 Plus Hybrid Inverter can automatically generate an output of up to 3kW in single phase even without having to install batteries.
Total Backup Power: by combining the inverter with a storage system, you can supply emergency power for single-phase consumption through the battery, with a time variation of less than 90 seconds. This produces a high autonomy and flexibility in situations in which there is a power outage. To make use of this function it is necessary to decouple from the network by means of contactors, thus preventing the Fronius from working in parallel with the electrical network and there being voltage in the line upstream of the meter.
Controlled active cooling: Through a dissipation system that has forced ventilation, we will have a longer useful life of the components. We will also have IP66 protection that will allow us to install it both indoors and outdoors.
Data Sheet
SYMO GEN24 PLUS |
Input Data |
Models |
3.0 |
4.0 |
5.0 |
Number of MPP followers |
|
2 |
DC input voltage range (Udc min - Udc max) |
V |
80-1000 |
Rated input voltage (Udc,r) |
V |
610 |
Commissioning voltage (start Udc) |
V |
80 |
MPP voltage range |
V |
80-800 |
80-800 |
80-800 |
|
|
MPPT1 |
MPPT2 |
MPPT1 |
MPPT2 |
MPPT1 |
MPPT2 |
Max input current per MPPT (Idc max.) |
A |
12,5 |
12,5 |
12,5 |
12,5 |
12,5 |
12,5 |
Maximum input current per MPPT (Idc max) |
A |
20 |
20 |
20 |
20 |
20 |
20 |
Number of DC entries in the module field |
|
2 |
1 |
2 |
1 |
2 |
1 |
|
|
MPPT1 |
MPPT2 |
Total |
MPPT1 |
MPPT2 |
Total |
MPPT1 |
MPPT2 |
Total |
Max DC power |
W |
3150 |
4180 |
5200 |
Max PV generator output |
Wpico |
4500 |
4500 |
4500 |
6000 |
6000 |
6000 |
6500 |
6500 |
6500 |
Output Data |
Models |
3.0 |
4.0 |
5.0 |
Rated AC power (Pac,r) |
W |
3000 |
4000 |
5000 |
Apparent power |
VA |
3000 |
4000 |
5000 |
Max output power |
VA |
3000 |
4000 |
5000 |
|
|
380 VCA |
400 VCA |
380VCA |
400 VCA |
380VCA |
400VCA |
AC output current nom. (@ 220 / 230V) |
A |
4,5 |
4,3 |
6,1 |
5,8 |
7,6 |
7,2 |
Grid coupling (Uac,r) |
V |
3~ EN 400/230 or 3~ EN 380/220 (+20 %/-30 %) |
Frequency (frequency range fmin - fmax) |
Hz |
50/60 (45 - 65) |
Nonlinear distortion coefficient |
% |
< 3,5 |
Power factor (cos φac,r) |
|
0,7 - 1 ind. / cap |
Models |
3.0 |
4.0 |
5.0 |
PV Point Output Data |
Rated Output Power PV Point |
VA |
3000 |
3000 |
30000 |
Coupling to the PV Point network |
V |
1~ NPE 220/230 |
Transition time |
Seg. |
< 20 |
Models |
3.0 |
4.0 |
5.0 |
Battery Connection |
Number of DC inputs |
|
1 |
Max input current (Idc max.) |
A |
12,5 |
DC input voltage range (Udc min - Udc max)3 |
V |
160-531 |
Battery DC connection technology |
|
Quick connectors by pressure of 2.5-10 mm² (1 unit BAT+ and 1 unit BAT-) |
Max DC input/output power 4 |
W |
3150 |
4180 |
5200 |
Max load power with AC4 coupling |
W |
3000 |
4000 |
5000 |
Compatible Batteries 5 |
|
BYD Battery-Box Premium HVS/HVM 5 y LG RESU FLEX |
- Isc pv = Isc max. ≥ Isc (STC) x 1.25, according to, for example, IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021
- The "Full Backup" option is available for Primo GEN24 from 3.0 to 6.0 Plus. For "Full Backup", additional external components are needed to network switching. More detailed information can be found in the instruction manual.
- Depending on connected battery
- Depending on country specific certification and availability
- Except BYD Battery-Box Premium HVS 12.8 and HVM 8.3
Models |
3.0 |
4.0 |
5.0 |
General data |
Dimensions (height × width × depth) |
mm |
530 X 474 X165 |
Weight (inverter / with packaging) |
kg |
15,6/19,4 |
15,6/19,4 |
15,6/19,4 |
protection type |
|
IP66 |
protection class |
|
1 |
nocturnal consumption |
W |
< 10 |
Overvoltage category (DC/AC)7 |
|
2/3 |
investor concept |
|
without transformer |
refrigeration |
|
Active Ventilation Technology |
Facility |
|
Indoor and outdoor installation |
Ambient temperature range |
ºC |
-25 a +60 |
Permissible air humidity |
% |
0-100 |
noise emission |
dB (A) |
<36 |
Max altitude |
M |
3000 / 4000 (unlimited / restricted voltage range) |
DC PV connection technology |
|
Quick connectors by pressure of 2.5-10 mm² (3 units CC+ and 3 units CC-) |
AC connection technology |
|
5-pole AC quick connector 1.5-10 mm² 3-pole quick connector for emergency power 1.5-10 mm² PE screw terminals 2.5-16 mm² (5 pieces) |
Certificates and compliance 8 |
|
IEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G98/99, R25 |
Emergency Power Features |
|
"PV Point" o "Full Backup" |
Country of manufacture |
|
Austria |
Life Cycle Analysis |
|
According to ÖNORM EN ISO 14040 and 14044 standards
(verified by the staff of the Fraunhofer IZM institute) |
Models |
3.0 |
4.0 |
5.0 |
Performance |
Max performance |
% |
98,1 |
98,2 |
98,2 |
European performance (ηEU) |
% |
96,7 |
97,2 |
97,5 |
MPP Fitting Performance |
% |
>99,9 |
>99,9 |
>99,9 |
Models |
3.0 |
4.0 |
5.0 |
Safety equipment |
DC insulation measurement |
Integrated |
Overload behavior |
Travel to duty point, power limitation |
DC disconnector |
Integrated |
Reverse polarity protection |
Integrated |
Models |
3.0 |
4.0 |
5.0 |
interfaces |
WLAN/2 × Ethernet LAN |
Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
6 digital inputs
6 digital inputs/outputs
|
Wave control receiver interface, power management |
Emergency stop (WSD) |
Integrated |
Datalogger and web server |
Integrated |
2 × RS485 |
Modbus RTU SunSpec (from another manufacturer) / Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot |
According to IEC 62109-1 standard. Optional DC SPD type 1+2 surge protection that can be retrofitted for two MPP trackers; available under the following article number: 4,240,313,CK