Grid inverter Fronius Primo 6.0 - 1 Light

Product no.: BET0632
1,769.00

Tax included and free shipment to spain



The Grid Inverter  Fronius Primo 6.0 - 1 Light have an IP65 degree of protection and snapinverter technology.

 

The Fronius Solar Inverter from the Primo series is a grid connection inverter without a transformer that allows the synchronization of the solar installation with the electrical grid.

All the models of the Fronius Primo series incorporate two and have an IP65 degree of protection. The Primo Lite/Light solar inverter models do not include Wlan communications for remote management and monitoring. The Primo series solar inverters have a standard interface to the internet via a Wlan or easy to integrate Ethernet cable. The Fronius Primo include datamanager and free connection to the solarweb portal.

 

Fronius solar inverters have a zero grid injection system which allows us to reduce the power of the inverter to prevent energy from being poured into the grid in the event that the solar installation produces more electricity than is being consumed.

The main advantages of the Fronius Primo series are:

- SnapInverter technology: The primo solar inverter is attached to the fixed wall bracket. In case of service it is not necessary to remove the entire inverter, but only the power stage to access the interior of the device. All wiring is kept in place to be able to handle the inverter wiring quickly and easily
- Integrated Data Communication: The Primo inverter can be connected to the internet via WLAN, ethernet without the need for additional modules. It can be connected via Modbus TCP SunSpec, Modbus RTU SunSpec or the Fronius Solar API (JSON).
- Smart Grid Ready: The Fronius solar inverter of the Primo series is ready to connect to smart grids so that they can remotely control the active and reactive energy injected into the grid.

 

TECHNICAL DATA FRONIUS PRIMO

DATA  IMPUT PRIMO 5.0-1 PRIMO6.0-1 PRIMO 8.2-1
Number of MPP followers 2
Max input current (Idc max 1/ Idc max 2) 12A/12A 18A/18A
Maximum short circuit current of MPP1/MPP2 (Isc pv) * 24 A / 24 A 36A/36A
DC input voltage range (Udc min. - Udc max.) 80 - 1000 V
Commissioning voltage (start Udc) 80 V
MPP voltage range 80 - 800 V
Number of DC inputs 2 + 2
Max PV generator output (Pdc max.) 7,5 kWpico  9,0 kWpico 12,3 kWpico

 

OUTPUT DATA PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 8.2-1
Rated AC power (Pac,r) 5.000 W 6.000 W 8.200 W
maximum power output 5.000 VA 6.000 VA 8.200 VA
AC output current (Iac nom.) 21,7 A 26,1 A 35,7 A
Grid coupling (voltage range) 1 ~ NPE 220 V / 230 V (180 V - 270 V)
Frequency (frequency range) 50 Hz / 60 Hz (45 - 65 Hz)
Nonlinear distortion coefficient < 3 %
Power factor (cos φac,r) 0,85 - 1 ind. / cap

 

GENERAL DATA PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 8.2-1
Dimensions (height x width x depth) 645 x 431 x 204 mm
Weight 21,5 kg
protection type IP 65
protection class 1
Overvoltage category (DC / AC) 1) 2 / 3
nocturnal consumption < 1 W
investor concept without transformer
Refrigeration Regulated air cooling
Facility Indoor and outdoor installation
Ambient temperature range -40 - +55 °C
Permissible air humidity 0 - 100 %
maximum altitude 4.000 m
DC connection technology 4x X+ and 4 x DC screw terminals 2.5 - 16 mm²
Main connection technology CONNECTIO3-pole AC screw terminals 2.5 - 16 mm²
Certificates and compliance

DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727,

AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 2)

Country of manufacture Austria

 

PERFORMANCE PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 8.2-1
Maximum performance 98,1 % 98,1 % 98,1 %
European Yield (ηEU) 97,1 % 97,3 % 97,5 %
MPP Fitting Performance > 99,9 %

 

SAFETY EQUIPMENT PRIMO 5.0 PRIMO 6.0-1 PRIMO 8.2-1
DC insulation measurement Yes
Overload behavior Duty point displacement, power limitation
DC disconnector Yes
Reverse polarity protection Yes

 

INTERFACES PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 8.2-1
WLAN / Ethernet LAN Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs Wave Control Receiver Interface
USB (Conector A) 2) Datalogging, inverter update via USB
2 RJ 45 connectors (RS422) 2) Fronius Solar Net
Warning output 2) Energy management (potential free relay output)
Datalogger and web server Including
External input 2) S0-Meter / Input interface for overvoltage protection
RS485 Modbus RTU SunSpec or meter connection

1) According to IEC 62109-1.

2) Also available in the light version.

 

Browse these categories as well: Solar inverters, Full catalogue